5.4.4 Calibration
No calibration is required.
5.4.5 Troubleshooting
If a problem is suspected, the TX320 may be checked by measuring the +12 V
and Ground terminal on the CR1000 PC-board wiring panel. Acceptable
readings are +11 to +14 Vdc. Check the SC12 cable connection between the
CR1000 wiring panel and the TX320. Press the TX320 diagnostic button to
query the state of the transmitter. If problems persist, obtain an RMA number
and return the device to Campbell Scientific for repair.
5.5 CR1000 Keyboard/Display
5.5.1
General Description
The CR1000 Keyboard/Display (pn CR1000KD) shown in FIGURE 5-3 is
used to check datalogger status, to display or plot sensor readings and stored
values, to enter numeric data, or to change port/flag state. The CR1000KD is
powered from the CR1000 printed circuit board “CS I/O” connector via our
9-pin serial cable (pn 10873) that ships with the RAWS.
Use the CR1000KD menus to enter GOES DCP-Setup
Parameters and to select the wind speed/direction sensor on the
RAWS.
NOTE
FIGURE 5-3. CR1000 Keyboard/Display
5.5.2
Wiring
The CR1000KD connects to the CR1000 PC board “CS I/O” 9-Pin connector
using our 9-pin serial cable (pn 10873) that ships with the RAWS.