FIGURE 4-5. 2-D WindSonic

Blue north
marker arrow

4.5.2.2 Wiring

The WindSonic4-LQ attaches to the connector labeled SDI-12; this connector
is color coded red. The sensor is internally wired from the RAWS connector
panel to the CR1000.

TABLE 4-5. SDI-12 Connector (color coded yellow)

Connector Pin

Description

CR1000 Terminal

A SDI-12

Signal

C7

B

12 V

12V

C Power

Ground

G

4.5.2.3 Maintenance

There are no user-serviceable parts on the 2-D Sonic Wind Sensor. Keep the
transducer paths clear of any obstructions. When clearing the transducer paths,
do not remove the “rubber” caps on each of the transducers.

4.5.2.4 Calibration

Recalibrate the 2-D Sonic Wind Sensor annually. Obtain an RMA number
before returning this sensor to Campbell Scientific for recalibration.

15