5 troubleshooting, 6 barometric pressure (optional), 1 general description – Campbell Scientific RAWS-F Remote Automated Weather Station for Fire Weather User Manual
Page 24: 2 wiring, Troubleshooting, Barometric pressure (optional), General description, Wiring, 6. barometric, Pressure
RAWS-F Remote Automated Weather Station for Fire Weather
4.5.2.5 Troubleshooting
If a problem is suspected, check the sensor cable. Disconnect the connector
and look for damaged pins. Try connecting a substitute sensor. Should the
2-D sonic sensor be damaged, fails to output data, or sends a nonzero
diagnostic, obtain an RMA number before returning this sensor to Campbell
Scientific for repair.
4.6 Barometric Pressure (optional)
4.6.1 General Description
The Setra Barometric Pressure Sensor (pn CS100) shown in FIGURE 4-6 is a
capacitive pressure transducer that uses Setra’s electrical capacitor technology
for barometric pressure measurements over the 600 to 1100 millibar range.
The CS100 is supplied in the triggered mode, in which the datalogger switches
12 Vdc power to the barometer before the measurement. The datalogger then
powers down the barometer after the measurement to conserve power.
FIGURE 4-6. Barometric pressure
4.6.2 Wiring
The CS100 is mounted inside the RAWS environmental enclosure and the
sensor wires are attached to the CR1000 printed circuit board wiring panel.
TABLE 4-6. CS100-QD Wiring
CS100 Wire Color CR1000 Terminal
Blue
5L
Yellow
Red 12V
Clear
G
Black G
Green C4
16