beautypg.com

2 ac/dc power, 2 plug in the battery, Ac/dc power – Campbell Scientific PS150/CH150 12 V Charging Regulators User Manual

Page 14: Plug in the battery, 5. ac power connections on ps150

background image

PS150/CH150 12 V Charging Regulators

3.1.2 AC/DC Power

Double check the input voltages coming in to the charger/regulator with a volt

meter.

AC Input Voltage: 14 to 24 VAC RMS

DC Input Voltage: 15 to 40 VDC

Exceeding the voltages listed above will damage the

power supply.

Disconnect the primary side of the AC/DC power before connecting wires to

the PS150.

Connect the secondary power supply leads to the two terminal blocks marked

“CHG”. There is no polarity on the “CHG” terminal blocks, so it does not

matter which wire goes to which “CHG” terminal block, but make sure there is

only ONE wire per block. See FIGURE 3-5.

FIGURE 3-5. AC power connections on PS150

3.2 Plug In the Battery

The battery used with the PS150 is shipped inside of the PS150 case if the

power supply is NOT installed inside an enclosure. If the PS150 is mounted

inside an enclosure then the battery will be located separately packed in one of

the packing boxes. This is done to minimize any damage that could occur if

the power supply should get loose from its mounts inside the enclosure during

shipment. The battery will NOT be plugged into the PS150. This is done to

minimize discharging the battery.

To remove the lid from the PS150, pull up on the PS150 lid latch and slide the

lid off as shown in FIGURE 3-6 and FIGURE 3-7.

WARNING

6