NL115 Ethernet and CompactFlash
®
Module
4.2.2 Step 2: LoggerNet Setup
The next step is to run LoggerNet and configure it to connect to the datalogger
via the Ethernet port.
a. In LoggerNet’s Setup Screen, press Add Root and choose IPPort. Input
the datalogger’s IP address and port number. The IP address and port
number are input on the same line separated by a colon. (The datalogger’s
default port number is 6785. It can be changed using Device
Configuration Utility or by modifying its value in the Status Table.)
b. Add a PakBus port and set the desired baud rate.
c. Add the datalogger (CR1000 or CR3000). Input the PakBus address of
the datalogger.
FIGURE 4-3. LoggerNet setup