Model HFP01SC Self-Calibrating Soil Heat Flux Plate

;Stop filtering data.
;
12: If time is (P92)
1: 39

Minutes (Seconds --) into a

2: 180

Interval (same units as above)

3: 30

Then Do


13: Do (P86)
1: 28

Set Flag 8 Low


;Compute in-situ calibration.
;
14: Z=X (P31)
1: 2

X Loc [ shf_mV ]

2: 6

Z Loc [ mV_end ]


15: Z=X*Y (P36)
1: 7

X Loc [ V_Rf ]

2: 7

Y Loc [ V_Rf ]

3: 3

Z Loc [ cal ]


16: Z=X*F (P37)
1: 3

X Loc [ cal ]

2: 128.7

F

3: 3

Z Loc [ cal ]


17: Z=X+Y (P33)
1: 4

X Loc [ mV_0 ]

2: 6

Y Loc [ mV_end ]

3: 9

Z Loc [ work ]


18: Z=X*F (P37)
1: 9

X Loc [ work ]

2: .5

F

3: 9

Z Loc [ work ]


19: Z=X-Y (P35)
1: 9

X Loc [ work ]

2: 5

Y Loc [ mV_180 ]

3: 9

Z Loc [ work ]


20: Z=ABS(X) (P43)
1: 9

X Loc [ work ]

2: 9

Z Loc [ work ]


21: Z=X/Y (P38)
1: 3

X Loc [ cal ]

2: 9

Y Loc [ work ]

3: 3

Z Loc [ cal ]


22: End (P95)

23: End (P95)

End Program

-Input Locations-
1 shf
2 shf_mV
3 cal
4 mV_0
5 mV_180
6 mV_end
7 V_Rf
8 shf_mV_a
9 work