Campbell Scientific EasyAG Probe for Soil Volumetric Water Content Profiles User Manual
Page 15

EasyAG
®
Soil Water Content Profile Probes
;Load measurement failure errors
13: If (X<=>F) (P89)
;Measurement of 0 at 1st sensor
1: 1
X Loc [ ES1_SF_1 ]
;indicates an inactive probe.
2: 1
=
;
3: 0
F
4: 30
Then
Do
14: Z=F x 10^n (P30)
;Set 1st sensor reading to -99999
1: -99999 F
2: 0
n, Exponent of 10
3: 1
Z Loc [ ES1_SF_1 ]
15: End (P95)
16: Beginning of Loop (P87)
;Loop to set error codes
1: 0
Delay
2: 8
Loop
Count
17: If (X<=>F) (P89)
;If 1st sensor reading is < -9999 i.e. = -99999
1: 1
X Loc [ ES1_SF_1 ]
;then set all sensor readings to -99999
2: 4
<
3: -9999
F
4: 30
Then
Do
18: Z=F x 10^n (P30)
1: -99999 F
2: 0
n, Exponent of 10
3: 1
-- Z Loc [ ES1_SF_1 ]
19: Z=F x 10^n (P30)
1: -99999 F
2: 0
n, Exponent of 10
3: 9
-- Z Loc [ ES1_WC_1 ]
20: Z=F x 10^n (P30)
1: -99999 F
2: 0
n, Exponent of 10
3: 17
-- Z Loc [ ES1_VIC_1 ]
21: Else (P94)
;Otherwise, if a sensor scaled frequency
;< -999, i.e. = -1000
22: If (X<=>F) (P89)
1: 1
-- X Loc [ ES1_SF_1 ]
2: 4
<
3:
-999
F
4: 30
Then
Do
23: Z=F x 10^n (P30)
;Set water content data to -99999
1: -99999 F
2: 0
n, Exponent of 10
3: 9
-- Z Loc [ ES1_WC_1 ]
11