Campbell Scientific EasyAG Probe for Soil Volumetric Water Content Profiles User Manual
Page 12

EasyAG
®
Soil Water Content Profile Probes
‘Load Measurement Failure Errors
If ES1_SF(1) = NAN Then ES1_SF(1) = -99999 ‘If probe fails (NAN at first sensor)
For X = 1 to 8 step 1
‘Load -99999 to all sensors
If ES1_SF(1) < -9999 Then
ES1_SF(X)
=
-99999
ES1_WC(X)
=
-99999
ES1_VIC(X)
=
-99999
Else
‘...OR...
If
ES1_SF(X)
<
-999
Then
‘If a WC sensor fails (indicated by -1000)
ES1_WC(X)
=
-99999
‘Load NAN for water content
Else
‘...OR...
ES1_WC(X) = ((ES1_SF(X) - c)/a)^(1/b) ‘apply calibration
EndIf
EndIf
Next
X
‘Measure rain
PulseCount
(Rain_mm,1,2,2,0,.01,0)
‘Input irrigation events manually in Irrimax, 0 must be written to data file
Irrig_mm
=
0
‘Output Data to Storage
CallTable
ES1_SF
‘Store Scaled Frequency and VIC Data with Rain and Irrigation
‘for Irrimax Software
CallTable
ES1_WC ‘Store Water Content Data
‘Next
Scan
Next
Scan
‘End Program
EndProg
8
- 014A Met One Wind Speed Sensor (36 pages)
- 020C Wind Direction Sensor (26 pages)
- 024A-L Met One Wind Direction Sensor (30 pages)
- 03001-L R.M. Young Wind Sentry Set (34 pages)
- 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors (40 pages)
- 034A-L WindSet (16 pages)
- 034B-L Met One Windset (34 pages)
- 036, 038 Spark Gapped Junction Box (6 pages)
- 05103, 05103-45, 05106, and 05305 R. M. Young Wind Monitors (30 pages)
- 083E Relative Humidity and Temperature Sensor (22 pages)
- 0871LH1 Freezing Rain Sensor (31 pages)
- 092 Barometric Pressure Sensor (24 pages)
- 10164-L Water Sampler Control Cable for use with Isco and Sigma Autosamplers (18 pages)
- 107-L Temperature Probe (28 pages)
- 108-LC Temperature Probe for MetData1 (12 pages)
- 108-L Temperature Probe (30 pages)
- 109-L Temperature Probe (30 pages)
- 109SS Temperature Probe (32 pages)
- 110PV Surface Temperature Probe (32 pages)
- 21108 RF450 Demo Kit (14 pages)
- 223-L Delmhorst Cylindrical Soil Moisture Block (28 pages)
- 227-L Delmhorst Cylindrical Soil Moisture Block (24 pages)
- 229 Water Matric Potential Sensor and CE4/CE8 (34 pages)
- 237-L Leaf Wetness Sensor (14 pages)
- 247-L Conductivity and Temperature (18 pages)
- 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors (36 pages)
- 25458 DIN-Rail Terminal Kit (10 pages)
- 255-100 Novalynx Analog Output Evaporation Gauge (16 pages)
- 260-953 Alter-Type Wind Screen for Tipping Bucket Rain Gages (14 pages)
- 27106T Gill Propeller Anemometer (18 pages)
- 30066 Battery Terminal Bus (1 page)
- 380, 385, 380M, 385M Met One Rain Gages (22 pages)
- 3WHB10K 3-Wire Half-Bridge Terminal Input Module (14 pages)
- 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield (40 pages)
- 4386 Battery Terminal Bus (1 page)
- 4WFB120, 4WFB350, 4WFB1K 4-Wire Full Bridge Terminal Input Module (22 pages)
- 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (46 pages)
- 4WPB100, 4WPB1K PRT Terminal Input Modules (16 pages)
- 52202 Electrically Heated Rain and Snow Gage (16 pages)
- 9522B Iridium Satellite Modem and COM9522B Interface Modem (46 pages)
- A100LK Anemometer (18 pages)
- A150 Desiccated Case (12 pages)
- A21REL-12 Relay Driver (10 pages)
- A6REL-12 Relay Driver (12 pages)
- AL200 ALERT2 Encoder, Modulator, and Sensor Interface (44 pages)