beautypg.com

Campbell Scientific CS616 and CS625 Water Content Reflectometers User Manual

Page 28

background image

CS616 and CS625 Water Content Reflectometers

Sensor lead

AM16/32

CR10X

CS616-1 green

1H

CS616-2 green

1L

CS616-3 green

2H

CS616-1,2,3 orange

2L

CS616-4 green

3H

CS616-5 green

3L

CS616-6 green

4H

CS616-4,5,6 orange

4L

...

CS616-46 green

31H

CS616-47 green

31L

CS616-48 green

32H

CS616-46,47,48

32L

RES

C1

CLK

C2

COM ODD H

SE1

COM ODD L

SE2

COM EVEN H SE3

COM EVEN L

C3

;{CR10X}
;
*Table 1 Program
01: 60

Execution Interval (seconds)


1: Batt Voltage (P10)

;Measure battery voltage

1: 1

Loc [ Bat_Volt ]


2: Internal Temperature (P17) ;Measure datalogger internal temperature
1: 2

Loc [ DL_Temp ]


3: If time is (P92)

;Every 60 Minutes Start Multiplexer Measurement Loop

1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 11

Set Flag 1 High


4: If Flag/Port (P91)

;User can start Measurement Loop by setting Flag 1 High

1: 11

Do if Flag 1 is High

2: 30

Then Do


5: Do (P86)

;Set control port 1 high (i.e. Reset Multiplexer)

1: 41

Set Port 1 High


6: Beginning of Loop (P87)

;16 loops X 3ea CS616 measured/loop

1: 0

Delay

2: 16

Loop Count

22