;{CR10X}
*Table 1 Program
01: 10.0000 Execution Interval (seconds)

; Measure CS300 pyranometer

1: Volt (SE) (P1)
1: 1

Reps

2: 24

250 mV 60 Hz Rejection Range ; use 500 mV range for the CR7 and

21X,

1000 mV range for the CR23X. For the

3: 1

SE Channel

CR10X, use range code 0 or 25 for

4: 1

Loc [ SlrW ]

> 1200 w/m

2

intensities.

5: 1.0

Multiplier

6: 0.0

Offset


; Set negative values to zero

2: If (X<=>F) (P89)
1: 1

X Loc [ SlrW ]

2: 4

<

3: 0

F

4: 30

Then Do


3: Z=F x 10^n (P30)
1: 0

F

2: 0

n, Exponent of 10

3: 1

Z Loc [ SlrW ]


4: End (P95)

; Convert mV to MJ/m2 for 10 second execution interval

5: Z=X*F (P37)
1: 1

X Loc [ SlrW ]

2: .00005 F
3: 2

Z Loc [ SlrMJ ]


; Convert mV to W/m2

6: Z=X*F (P37)
1: 1

X Loc [ SlrW ]

2: 5

F

3: 1

Z Loc [ SlrW ]


7: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


8: Set Active Storage Area (P80)
1: 1

Final Storage Area 1

2: 101

Array ID


9: Real Time (P77)
1: 1220

Year,Day,Hour/Minute (midnight = 2400)


10: Average (P71)
1: 1

Reps

2: 1

Loc [ SlrW ]


11: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 1440

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)

B-2