Appendix B. Edlog Programming Examples

49: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


50: Set Active Storage Area (P80)
1: 1

Final

Storage

Area

1

2: 101

Array

ID


51: Real Time (P77)
1: 1220

Year,Day,Hour/Minute

(midnight

=

2400)


52: Average (P71)
1: 1

Reps

2: 4

Loc

[

AirTempC

]


53: Average (P71)
1: 1

Reps

2: 7

Loc

[

DewPnt_C

]


54: Average (P71)
1: 1

Reps

2: 8

Loc

[

WetBlb_C

]


55: Average (P71)
1: 1

Reps

2: 6

Loc [ WBGT_C ]


56: Sample (P70)
1: 17

Reps

2: 3

Loc [ BGTemp_C ]


;Daily station status data.

57: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 1440

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


58: Set Active Storage Area (P80)
1: 1

Final

Storage

Area

1

2: 102

Array

ID


59: Real Time (P77)
1: 1220

Year,Day,Hour/Minute

(midnight

=

2400)


60: Maximum (P73)
1: 1

Reps

2: 0

Value

Only

3: 1

Loc [ BattVolt ]


61: Minimum (P74)
1: 1

Reps

2: 0

Value

Only

3: 1

Loc [ BattVolt ]

B-6