beautypg.com

Campbell Scientific BlackGlobe Temperature Sensor for Heat Stress User Manual

Page 22

background image

Appendix B. Edlog Programming Examples

6: If (X<=>F) (P89)

1: 5

X Loc [ AirRH ]

2: 4

<

3: 108

F

4: 30

Then

Do


7: Z=F x 10^n (P30)

1: 100

F

2: 0

n,

Exponent

of

10

3: 5

Z Loc [ AirRH ]


8: End (P95)


9: End (P95)

;BlackGlobe temperature - °C

10: AC Half Bridge (P5)
1: 1

Reps

2: 23

25 mV 60 Hz Rejection Range

3: 3

SE

Channel

4: 1

Excite

all

reps

w/Exchan

1

5: 1000

mV

Excitation

6: 3

Loc [ BGTemp_C ]

7: 200

Multiplier

8: 0

Offset


11: Polynomial (P55)
1: 1

Reps

2: 3

X Loc [ BGTemp_C ]

3: 3

F(X) Loc [ BGTemp_C ]

4: -26.97 C0
5: 69.635 C1
6: -40.66 C2
7: 16.573 C3
8: -3.455 C4
9: 0.301

C5


;Calculate saturated vapor pressure.

12: Saturation Vapor Pressure (P56)
1: 4

Temperature Loc [ AirTempC ]

2: 9

Loc [ SVP_kPa ]


;Calculate vapor pressure.

13: Z=X*Y (P36)
1: 9

X Loc [ SVP_kPa ]

2: 5

Y Loc [ AirRH ]

3: 10

Z Loc [ VP_kPa ]


14: Z=X*F (P37)
1: 10

X Loc [ VP_kPa ]

2: 0.01

F

3: 10

Z Loc [ VP_kPa ]

B-2