beautypg.com

Campbell Scientific BlackGlobe Temperature Sensor for Heat Stress User Manual

Page 25

background image

Appendix B. Edlog Programming Examples

37: Z=X (P31)

1: 12

X Loc [ new_wbT ]

2: 14

Z Loc [ UpperTmp ]


38: Else (P94)


39: Z=X (P31)

1: 12

X Loc [ new_wbT ]

2: 15

Z Loc [ LowerTmp ]


40: End (P95)


41: If (X<=>F) (P89)

1: 16

X Loc [ Diff_wbT ]

2: 4

<

3: 0.01

F

4: 31

Exit Loop if True


42: End (P95)

;Wet-bulb temperature.

43: Z=X (P31)
1: 12

X Loc [ new_wbT ]

2: 8

Z Loc [ WetBlb_C ]


;Calculate Wet-Bulb Globe (HUMIDEX) temperature.

44: Z=X*F (P37)
1: 4

X Loc [ AirTempC ]

2: 0.1

F

3: 20

Z Loc [ scratch1 ]


45: Z=X*F (P37)
1: 3

X Loc [ BGTemp_C ]

2: 0.2

F

3: 21

Z Loc [ scratch2 ]


46: Z=X*F (P37)
1: 7

X Loc [ DewPnt_C ]

2: 0.7

F

3: 6

Z Loc [ WBGT_C ]


47: Z=X+Y (P33)
1: 20

X Loc [ scratch1 ]

2: 6

Y Loc [ WBGT_C ]

3: 6

Z Loc [ WBGT_C ]


48: Z=X+Y (P33)
1: 21

X Loc [ scratch2 ]

2: 6

Y Loc [ WBGT_C ]

3: 6

Z Loc [ WBGT_C ]


;Store hourly data.

B-5