beautypg.com

1 cr1000 example program – Campbell Scientific 52202 Electrically Heated Rain and Snow Gage User Manual

Page 12

background image

52202 Electrically Heated Rain and Snow Gage

5.2.1 CR1000 Example Program

'CR1000

'RM_Young Tipping Blk > C4
' Wht > 5v
'Cabling for heater goes to 24VAC power supply

'Declare Variables and Units
Public BattV
Public RM_Young

Units BattV = Volts
Units RM_Young =inch

DataTable(OneMin,True,-1)
DataInterval(0,1,Min,10)
Totalize

(1,RM_Young,FP2,False)

EndTable

'Define Data Tables
DataTable(OneDay,True,-1)
DataInterval(0,1440,Min,10)
Minimum(1,BattV,FP2,False,False)
Totalize

(1,RM_Young,FP2,False)

'RM Young tipping bucket

EndTable

'Main Program
BeginProg
Scan(5,Sec,1,0)

'Default Datalogger Battery Voltage measurement BattV

PanelTemp

(PTemp,_60Hz)

Battery(BattV)

'RM Young Heated Rain Gage measurement Rain_in

PulseCount(RM_Young,1,14,2,0,0.0039,0)

'Call Data Tables and Store Data

CallTable(OneMin)
CallTable(OneDay)
NextScan
EndProg

8