3 cr10x example program, 2 control port example – Campbell Scientific 52202 Electrically Heated Rain and Snow Gage User Manual

Page 11

background image

52202 Electrically Heated Rain and Snow Gage

5.1.3 CR10X Example Program

;{CR10X}
*Table 1 Program
01: 1.0000 Execution

Interval

(seconds)


1: Pulse (P3)
1: 1

Reps

2: 1

Pulse

Channel

1

3: 2

Switch Closure, All Counts

4: 3

Loc

[

Rain_mm

]

5: 0.1

Multiplier

6: 0

Offset


2: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


3: Set Active Storage Area (P80)
1: 1

Final Storage Area 1

2: 101

Array

ID


4: Real Time (P77)
1: 1220

Year,Day,Hour/Minute

(midnight

=

2400)


5: Totalize (P72)
1: 1

Reps

2: 3

Loc

[

Rain_mm

]


*Table 2 Program
01: 0

Execution

Interval

(seconds)


*Table 3 Subroutines

End Program

5.2 Control Port Example

The following example programs use a control port to read the output from the
precipitation gage. The CR1000 example will also work with the CR800,
CR850, and CR3000. The CR10X program will also work with the CR500,
CR510, or CR23X.

7