255-100 Novalynx Analog Output Evaporation Gauge

2. Specifications

FIGURE 1. 255-100 Connected to 255-200 Using 255-100P/F

255-100 Novalynx Analog Output Evaporation Gauge
Height:

27 1/2” (700 mm)

Diameter: 8”

(203

mm)

Weight:

7 1/2 lbs (3.4 kg)

Shipping weight:

15 lbs (6.8 kg)

Cable:

50' of 3-conductor, 24 AWG, shielded

Float: 4”

diameter,

plastic

Counterweight:

4 oz (114 g), stainless steel

Water input port:

1/2” NPT coupling, female

Base dimensions:

16” (40.6 cm) triangle with leveling screws

Total resolution:

0.03” (0.76 mm)

Accuracy: 0.25%
Rotation: 360°

continuous

Electrical angle:

340°, ±1° (20° gap)

Resistance: 1,000

ohms,

±10%

Operating temperature: -40° to +60°C
Linearity: 0.25%
Mechanical range:

0 to 10” (0 – 254 mm)

Electrical range:

0 to 9.44” (0 – 240 mm)

FIGURE 2. 255-100 Novalynx Analog Output Evaporation Gauge