10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers

3: Do (P86)
1: 10

Set high Flag 0 (output flag)


4: Set Active Storage Area (P80)
1: 1

Final Storage Area 1

2: 400

Array ID or location


5: Real Time (P77)
1: 1110

Year,Day,Hour-Minute


6: Sample (P70)
1: 1

Reps

2: 10

Loc [ Sample_No ]


7: End (P95)

;of Subroutine Number 98


End Table 3

4.2.3 Inhibit Sampler’s Program

Wire Color

CR10(X)

Purple

G

(Isco) Green

C1

(Sigma) Brown C1

Clear

G

To inhibit an Isco sampler from running its own program, set control port 1

low using a program control instruction such as Instruction 86. To allow the

sampler to run its program, set it high.

The logic for Sigma samplers is just the opposite. A high signal

inhibits the sampler.

Example for inhibiting an Isco sampler's program:

Do (P86)
1: 51

Set Port 1 low

; (41 would set it high)

NOTE

9