4. electrical performance, Specification model no – Samlex America ST1500-148 User Manual
Page 8

7
2-4. Electrical Performance
Specification
Model No.
Item
ST1500-112 ST1500-124 ST1500-148 ST1500-212 ST1500-224 ST1500-248
Continuous Output Power
1500W
Maximum Output Power (3Min.)
1725W
Surge Rating
3000W
Input Voltage
12V
24V
48V
12V
24V
48V
Output Voltage
100 / 110 / 120V ±
5%
220 / 230 / 240V ± 3%
Frequency
(Switch Selectable)
50 / 60Hz
Output Waveform
Pure Sine Wave (THD < 3%)
Efficiency (full load)
88%
91%
92%
92%
93%
94%
No Load Current Draw
1.45A
0.75A
0.40A
1.40A
0.70A
0.40A
Stand-By Current Draw
0.28A
0.15A
0.09A
0.28A
0.15A
0.09A
Input Voltage Regulation
10.5-15
VDC
21.0-30
VDC
42.0-60
VDC
10.5-15
VDC
21.0-30
VDC
42.0-60
VDC
Input Level Indicator
Red / Orange / Green LED
Load Level Indicator
Failure Indicator
Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over Temperature
Over/Under Input Voltage, AC Input Circuit Breaker
Circuit Breaker
30 Amp
10 Amp
Remote Control Unit
CR6 / CR8 Optional
Synchronous AC transfer
YES
Transfer switch
30 Amp
10Amp
Transfer Time
Inverter to utility AC : 8 ~ 10msec. ; Utility AC to inverter : 16 ~ 50 msec
Safety
Meet UL458
------
EMC
EMI Conduction&Radiation
Compliance to FCC Class A
Compliance to EN55022 classA
EMS Immunity
------
Compliance to EN61000-3-2,3
LVD
------
Compliance to EN60950-1
e-MARK
------
Compliance to e-13*72/245/ECC,95/54 EC
Operating Temperature Range
0 - 40
℃
℃
℃
℃
Storage Temperature Range
-30
℃
℃
℃
℃ to 70℃
℃
℃
℃
Cooling
Loading controlled cooling fan
Dimensions
403(L)*236(W)*115(H) mm / 15.9(L)*9.29(W)*4.53(H) Inch
Weight
7.0 kg / 15.4 Lbs.
Note: The specifications are subject to change without notice.