beautypg.com

Samlex America ST1500-148 User Manual

Page 14

background image

13

3-1-3 Green terminal

1) Before installing the inverter, you need to ensure the main switch must

be ”OFF”.

2) Before using the remote control terminal, you need to ensure the main

switch muse be “REMOTE”.

3) Ensure the remote contacts off.
4) Use 20 ~ 24 #AWG wire to connect the remote control terminal.
5) Remote control ON/OFF inverter setup status:

ENB

GND

ON:INV. ON

OFF:INV. OFF

LOW:INV. OFF

HI:INV. ON

GND

ENB

TR

(TR ON)

(TR OFF)

OFF:INV. OFF

ON:INV. ON

ENB

BAT+
BAT-

GND

ON:INV. ON

OFF:INV. OFF

ENB

+

-

DC

POWER

NOTE: At the same time, only can use one model to control the inverter.

The maximum level is the same as input DC voltage.

3-1-4. Remote Port:

The ST Series Inverter is compatible with any of these remote

controllers: CR-6 or CR-8.

3-1-5. Input Level:Display Input Voltages

LED Status

DC 12V

DC 24V

DC 48V

RED Blink (slow)

10.3~10.6

20.5~21.2

40.8~42.4

RED

10.6~11.0

21.2~21.8

42.4~43.5

ORANGE

11.0~12.1

21.8~24.1

43.5~48.1

GREEN

12.1~14.2

24.1~28.6

48.1~56.3

ORANGE Blink

14.2~15.0

28.6~30.0

56.3~59.6

OVER RED BLINK

15.0

30.0

59.6