Samlex America ST1500-148 User Manual
Page 14

13
3-1-3 Green terminal
1) Before installing the inverter, you need to ensure the main switch must
be ”OFF”.
2) Before using the remote control terminal, you need to ensure the main
switch muse be “REMOTE”.
3) Ensure the remote contacts off.
4) Use 20 ~ 24 #AWG wire to connect the remote control terminal.
5) Remote control ON/OFF inverter setup status:
ENB
GND
ON:INV. ON
OFF:INV. OFF
LOW:INV. OFF
HI:INV. ON
GND
ENB
TR
(TR ON)
(TR OFF)
OFF:INV. OFF
ON:INV. ON
ENB
BAT+
BAT-
GND
ON:INV. ON
OFF:INV. OFF
ENB
+
-
DC
POWER
NOTE: At the same time, only can use one model to control the inverter.
The maximum level is the same as input DC voltage.
3-1-4. Remote Port:
The ST Series Inverter is compatible with any of these remote
controllers: CR-6 or CR-8.
3-1-5. Input Level:Display Input Voltages
LED Status
DC 12V
DC 24V
DC 48V
RED Blink (slow)
10.3~10.6
20.5~21.2
40.8~42.4
RED
10.6~11.0
21.2~21.8
42.4~43.5
ORANGE
11.0~12.1
21.8~24.1
43.5~48.1
GREEN
12.1~14.2
24.1~28.6
48.1~56.3
ORANGE Blink
14.2~15.0
28.6~30.0
56.3~59.6
OVER RED BLINK
15.0
30.0
59.6