14
3-1-6. Load Level:Display AC Loads (Watts)
LED Status
DARK
GREEN
ORANGE
RED
BLINKING
RED
ST1000
0 ~ 80W
80 ~ 330W
330 ~ 750W
750 ~ 960W
Over 960W
ST1500
0 ~ 120W
120 ~ 495W
495 ~ 1125W 1125 ~ 1450W Over 1450W
ST2000
0 ~ 160W
160 ~ 660W
660 ~ 1500W 1500 ~ 1920W Over 1920W
ST2500
0 ~ 200W
200 ~ 825W
825 ~ 1875W 1875 ~ 2390W Over 2390W
3-1-7. Power Status:Display Power & Fault Status
Orange LED
LED Signal
Status
Solid
Power OK
Slow Blink
Power Saving
Red LED
LED Signal
Status
Fast Blink
OVP
Slow Blink
UVP
Intermittent Blink
3 3 3 3 3 3
OTP
Solid
OLP
Green LED
LED Signal
Status
Solid
AC GRID INPUT OK
3-1-8. AC Frequency:Selected by “S4” Dip Switch
Frequency
S4
50 HZ
OFF
60 HZ
ON
3-1-9. Power Saving Mode: Power Saving Mode is adjustable and
set by the Dip Switches, S1, S2 and S3 on the front panel.
Example: The load should be set above15W. If the load is below15W,
the power saving mode will be activated.