beautypg.com

Check the system, Save these instructions – LBL Lighting 2-Circuit MO Rmt Mag Xfmr 600w 277v/12v User Manual

Page 4

background image

COMX X1

X2

X3

X4 COMY Y1

Y2

Y3

Y4

4

Check the System

After installing the entire low voltage system, if the
lamps have low intensity, then measure the voltage at
the fixture closest to the power feed contacts with a
voltmeter. The system must be at least 80% loaded and
the voltmeter should read between 11V - 12V ~AC. If
the voltage does not fall in this range, call Encompass
Lighting Group "Technical Support" at 847-410-4606.

After installing the entire system, operate the system for
five minutes. On the low voltage side, all electrical
connection points should be no more than warm to the
touch. If a connection is hot to the touch, retighten the
connection and check to ensure that the temperature
decreases.

The transformer circuit breaker will trip if there is a short
in the system. After removing the cause of the short, the
circuit breaker needs to be reset to power the system
up.

Replace the transformer cover and tighten the two
Phillips screws on the sides of the transformer.

PHILLIPS
SCREW

1

2

3

4

3A

CIRCUIT
BREAKER

CIRCUIT
BREAKER

3

3

4

4

SAVE THESE INSTRUCTIONS!

7400 Linder Ave, Skokie, IL 60077

847.410.4400

www.encompasslighting.com

© 2008 Encompass Lighting Group. All rights reserved. The "Encompass Lighting Group"
graphic is a registered trademark of Encompass Lighting Group. Encompass Lighting Group
reserves the right to change specifications for product improvements without notification.

A Generation Brands Company