6.8
Initialize Large Numbers
Syntax
Hexadecimal
0xFE 0x6E
Decimal
254 110
ASCII
254 “n”
Description
This command will load the default large number characters into the
volatile memory. If you have stored your own custom large numbers,
use the ’Load Custom Characters’ command instead to load your
custom character data into the volatile memory. This command will
allow you to use the ’Place Large Numbers’ command.
Remembered
No
6.9
Place Large Number
Syntax
Hexadecimal
0xFE 0x23 [Col] [Digit]
Decimal
254 35 [Col] [Digit]
ASCII
254 “#” [Col] [Digit]
Parameters
Parameter
Length
Description
Col
1
The column number.
Digit
1
Large number to place (0-9).
Description
This command will place a large number (four columns high) at the
[row] and [col] specified.
NOTE
Large Numbers must be initialized before this command is executed.
Remembered
No
6.10
Initialize Horizontal Bar
Syntax
Hexadecimal
0xFE 0x68
Decimal
254 104
ASCII
254 “h”
Description
This command will load the default horizontal bar characters into the
volatile memory. If you have stored your own custom horizontal bar
data, use the ’Load Custom Characters’ command instead to load your
custom bar data into the volatile memory. This command will allow you
to use the ’Place Horizontal Bar’ command.
Remembered
No