beautypg.com

Ashcroft 80-81 - Isolation Rings User Manual

Page 9

background image

9

Step 3: Tighten the piping flange bolts to the locking nuts / washers on the opposite flange. Each should be
tightened by cross-bolting with the proper torque based as described in ASME PCC-1 on NPS, ANSI/ASME
Class rating, and gasketing used.

ASSEMBLY REMOVAL

IMPORTANT: In the event the assembly needs to be removed from process, follow the manufacturer’s rec-
ommended procedure to prevent possible injury and/or damage.

A. Confirm process has been shut down with process pressure relieved and piping drained, cleaned and

dried before installation and/or removal of product assembly.

B. Ensure the assembly is supported prior to removal of bolts/flanges.

PIPE FLANGE
(NPS 4", CLASS 300 SHOWN)

CENTERING GAGE

ISOLATION RING
(NPS 4", TYPE 80 SHOWN)

FLANGE BOLT

INSTRUMENT REMOVAL DEVICE
(NEEDLE VALVE SHOWN)

ASSEMBLY FLANGE

ASSEMBLY SCREW

FLEXIBLE LINER

SENSING FLUID

FILL PORT

CENTER BODY

FLANGE GASKET

FLANGE BOLT

6- ASSEMBLY REMOVAL

I&M008-10223_USER_layout 6/17/14 3:27 PM Page 9