Table 2-1. baud rate settings, Table 2-2. parity settings, Table 2-3. factory settings – MagTek MT-211232 RS-232 3-TRACK User Manual
Page 20

RS-232 Swipe Reader, 3-Track
14
Table 2-1. Baud Rate Settings
Baud Rate
SW1
SW2
2400 OFF OFF
4800 ON OFF
9600 OFF ON
19200 ON ON
Table 2-2. Parity Settings
Parity SW3 SW4
Description
ODD OFF OFF
Parity
Enabled
MARK ON OFF
Parity
Disabled
EVEN OFF ON
Parity
Enabled
SPACE ON
ON
Parity
Disabled
Switch 5: This is an option switch that sends Start of Text (STX) and End of Text (ETX)
framing characters when set to the ON position. If framing characters are not desired, set
Switch 5 to the OFF position.
Switch 6: This is an option switch that sends one Carriage Return (CR) after the last
track when set to the ON position. If this control character is not desired, set Switch 6 to
the OFF position.
Switch 7: This is an option switch that sends the Start Sentinel (SS) and the End Sentinel
(ES) framing characters when set to the ON position. If the framing characters are not
desired, set Switch 7 to the OFF position.
Switch 8: When Switch 8 is OFF, the unit is in the unbuffered mode, and data is
automatically sent to the PC without being requested. When ON, the unit is in the
buffered mode, and data is not sent to the PC until the Reader receives an Inquiry
Command.
The switches are preset at the factory as shown in Table 2-3.
Table 2-3. Factory Settings
Switch Setting
Description
SW1 OFF
SW2 ON
Baud Rate 9600
SW3 OFF
SW4 OFF
1 Start Bit, 7 Data Bits
Odd Parity, 1 Stop Bit
SW5 ON
Send STX and ETX
SW6 ON
Send CR
SW7 ON
Send SS and ES
SW8 OFF
Unbuffered Mode