Msr direction property – MagTek IntelliStripe 310™ User Manual
Page 37

Section 6. Transport Application
31
MSR DIRECTION PROPERTY
Property ID: 04 (Hex)
Property Type: Dword
Power Up/Reset Value: 1 (Consume)
Get/Set support: Both
Description:
This property is used to control the magnetic stripe read direction.
Values:
Value State
Description
0
Both
The reader can read during both card consuming and ejecting.
1
Consume
The reader can only read during card consuming.
2
Eject
The reader can only read during card ejection.
Note: If the front-gate option is installed, the IntelliStripe 310 Reader will be incapable of
reliably reading mag-stripe cards during the card ejection cycle. Reliable mag-stripe card
reading will only be possible during the card consumption cycle. If mag-stripe reading is
required during the card ejection cycle, then the product must be ordered without the front-gate
option.
Example Set Property Request:
Field MTYP
APPL
CMND
RC
PTYP
PID
Byte
1
2 3 4 5 6
Value
(Hex)
00
82 01 00 01 04
Field PVAL
Byte
7 - 10
Value (Hex)
01 00 00 00 (Consume)
Example Set Property Response:
Field MTYP
APPL
CMND
RC
Byte 1
2
3
4
Value (Hex)
40
82
01
00