Notify read state property – MagTek IntelliStripe 310™ User Manual
Page 20

IntelliStripe 310 Command Reference
14
NOTIFY READ STATE PROPERTY
Property ID: 00 (Hex)
Property Type: Dword
Power Up/Reset Value: 0 (OFF)
Get/Set support: Both
Description:
If the notify read state is not set to OFF, then a notification message will be sent to the host when
a card is read. The notification message will have the same syntax as the command response of
the command that corresponds to the notify read state. The only difference is that the message
header will contain a notification message type instead of a response message type. Note that
when the Notify Read State is set to GET TRACK DECODE DATA, the track number is
obtained from the Notify Read Track Property.
Values:
Value
Notify Read State
0 OFF
1
GET TRACK 123 DECODE DATA
2
GET TRACK DECODE DATA
Example Set Property Request:
Field MTYP
APPL
CMND
RC
PTYP
PID
Byte
1
2 3 4 5 6
Value
(Hex)
00
01 01 00 01 00
Field PVAL
Byte
7 - 10
Value (Hex)
02 00 00 00 (GET TRACK DECODE DATA)
Example Set Property Response:
Field MTYP
APPL
CMND
RC
Byte 1
2
3
4
Value (Hex)
40
01
01
00