Microcontroller led indicator, External auto-ranging power pack, Auto-ranging input – MagTek INTELLISTRIPE 380 USB/RS-232 User Manual
Page 16: Output rating, Firmware, Memory cards, Flash download protection

IntelliStripe 380 USB/RS-232
8
Microcontroller LED Indicator
The Main PCB supports a “watchdog” LED, which blinks on and off providing visual indication
that the microcontroller is in a normal state of operation. The LED can be viewed when the
bottom access hatch is removed from the enclosure.
External Auto-Ranging Power Pack
The Reader/Encoder is powered from an external power-pack, which is located near the Host
Computer System. Power is routed to the Reader/Encoder through the Host RS-232 cable.
Auto-Ranging Input
The external power pack features an Auto-ranging AC input that allows for direct connection to
either a 100 VAC or 220 VAC, 50 to 60 Hz.
Output Rating
The power pack is rated at approximately +12 VDC @ 4 A
± 5%.
Firmware
The firmware for the Reader/Encoder is based upon existing MCP protocol and command set.
Memory Cards
The firmware supports smartcard interfaces to memory cards.
FLASH Download Protection
To prevent illegal applications from being downloaded into the Reader/Encoder, the firmware
verifies that the downloaded FLASH program is provided (authorized) by MagTek. If the
program cannot ID itself correctly, the boot loader program abandons the FLASH load sequence
and returns a unique status code that identifies the situation to the Host.