2 authorizing the device, 1 about authorization, Authorizing the device – MagTek EC2000 99875600 User Manual
Page 64: About authorization, On 8.2 authorizing the device, 8 - configuration
8 - Configuration
ExpressCard 2000| Instant Issuance Card Personalization System | User Installation and Operation Manual
Page 64
Figure 8-1 - Static IP Address Settings
9) If you are configuring a proxy server:
a) Press the
Advanced
button to open the
Proxy Settings
page.
b) Make sure the Use Proxy checkbox is turned ON.
c) Select each of the fields on the page, and use the on-screen keyboard to enter values.
d) Double-check the values you have entered, then press the
Save
button to confirm them.
e) Press the
Back
arrow to return to the
TCP/IP Utility
page.
10) Network configuration is complete. Press the
Status
button to return to the
Status
page.
8.2 Authorizing the Device
8.2.1 About Authorization
As a security measure, the EC2000 is shipped in the Deauthorized state, meaning personalization
features are not available. When deauthorized, the
Status
page shows a message in the lower status area
stating “Error Machine is Deauthorized.” Contact MagTek Support Services to obtain default passwords
and for instructions to authorize the device (see section 8.4 Passwords for more information).
Every 24 hours after the EC2000 is authorized, the device will automatically attempt to connect to
MagTek’s Certificate Authority (CA) to re-authorize. This requires the device to be powered on and
connected to the Internet [see section 8.1 Network (TCP/IP) Configuration].
If re-authorization does not occur within 7 days, the EC2000 will stop issuing personalized cards until it
is able to connect to the CA and re-authorize its security certificate. The device will continue to create
sample cards even when deauthorized.
The time remaining until the next required re-authorization can be viewed using the
Device Information
button on the
Help
page (see section 6.3.3 About the Help Page). In some circumstances (for example,
if a lengthy power or network outage has caused the EC2000 to deauthorize and the automatic re-
authorization will not happen soon enough), it may be necessary to re-authorize the EC2000 manually.