MagTek IMAGESAFE99875500 User Manual
Page 77
Section 7. Other Keys Available from Device
69
USBSpeed
This key specifies the protocol of USB connection.
Values
Value Description
HI
The current USB connection is USB2.0
LOW
The current USB connection is USB1.1
StartTimeout
This key specifies the firmware Timeout on check entry.
Values
Value Description
numeric value
Time, in milliseconds
RawSensors
This key contains a decimal number that can be masked to determine the status of a particular sensor or
the status of a print cartridge or the status of the cover switch. When the value of a masked bit equals
zero, this typically indicates a normal or default operational state. For example, depending on the masked
bit, the zero value may indicate that the cover is detected, the ink cartridge is installed, or the sensor is
unblocked.
Masked Values
Value Description for Excella STX
0x00001
0 = sensor at check entry 1 unblocked
0x00002
0 = sensor at check entry 2 unblocked
0x00004
0 = sensor at entry pinch unblocked
0x00008
0 = sensor at MICR head unblocked
0x00010
0 = sensor just past back printer unblocked
0x00020
0 = sensor just before front printer unblocked
0x00040
0 = sensor at exit pinch unblocked
0x00080
0 = sensor at exit 2 unblocked
0x00100
0 = sensor at exit 1 unblocked
0x00400
0 = back ink cartridge installed
0x00800
0 = front ink cartridge installed
0x10000
0 = cover detected
Masked Values
Value Description for Excella
0x0001
0 = sensor at manual feeder unblocked
0x0002
0 = sensor at MICR head unblocked
0x0004
0 = sensor just past back printer unblocked
0x0008
0 = sensor at exit pinch unblocked
0x0020
0 = sensor at auto feeder unblocked
0x0040
0 = access guide latched
0x0080
0 = sensor at operator button unblocked
0x0100
0 = back ink cartridge installed