MagTek IMAGESAFE99875500 User Manual
Page 50

ImageSafe Windows API Specifications
42
SECTION = Application
The Application section includes keys to configure some required characteristics of the unit.
Transfer
This key determines the file transfer method.
Values
Value Description
HTTP
Default: Transfer files using HTTP protocol
FTP
Transfer files to FTP server
DocUnits
This key determines the unit of measurement.
Values
Value Description
ENGLISH
Default: Dimensions in thousandths of an inch
METRIC
Dimensions in millimeters
SECTION = ProcessOptions
The ProcessOptions section includes keys that control various operational options during the transaction.
ReadMICR
This key selects the MICR font to be read on the check.
Values
Value Description
E13B
Decode only E13B character set
CMC7
Decode only CMC7 character set
ALL
Auto-detect and decode both E13B and CMC7
NO
Suppress MICR reading
Endorse
This key determines what type of printing is required on the check.
Values
Value Description
NO
No printing required
BACK
Request printing on the back (endorsing)
FRONT
Request printing on the front (franking).
BOTH
Request printing on the back and the front (endorsing and franking).
RespondEarly
This key determines if an early response is required from the device.
Values
Value Description
YES
Request device to respond as early as possible. Images may not be ready.
NO