beautypg.com

Current monitoring – Agilent Technologies E3614A User Manual

Page 43

background image

1-10-5

Figure 6

Set the CC switch down, and all others up.

I

in

= 1/A x I

out

I

out

= A x V

in

Where

I

out

is the power supply output current in amps.

I

in

is the programming current in

µ

amps.

A is the gain.

Programming currents can be increased by adding a resistor across the CC+ and CC-. A
10 volts drop across R1 represents full scale current of the power supply. When a 1 kohm
resistor is added across R1, the programming currents are as follows with the
programming current in mA.

Current Monitoring

Current of the power supply can be monitored across the internal current monitoring
resistor. One side of the resistor is at the +output and A3; the other side of the resistor
is at A1. The table below shows the resistor value and conversion factors. To obtain
the current divide the measured voltage by the resistor value or multiply the amps/V
times the voltage measured.

Model

A (A/

µ

A)

1/A (

µ

V/A)

E3614A

0.055

18

E3515A

0.0278

35.9

E3616A

0.0158

63.4

E3617A

0.00928

108

Model

A (A/mV)

1/A (mA/A)

Parallel resistor required for a

1 amp/mamp value of A (kohm)

E3614A

0.594

1.69

1.7

E3515A

0.297

3.37

3.45

E3616A

0.168

5.95

6.28

E3617A

0.0989

1.01

11.2

Model

Resistor

value (

)

amps/V

E3614A

0.1

10

E3515A

0.2

5

E3616A

0.6

1.67

E3617A

0.89

1.12