7.1.3 90/240Vac wiring version
Control cable
Power supply
Fig. 7
7.1.3.1 90/240Vac version power supply
cable
The device is Class I. Connection of the
yellow-green cable to the safety ground
is therefore necessary to ensure electrical
safety.
The illuminator is provided with a 2m power cable.
Blue, brown, yellow/green power cables: Connect
the brown cable to the phase, the blue one to the
neutral and the yellow-green one to the safety
ground.
For maximum distances and recommended cable
sections, refer to the relative paragraph.
7.1.3.2 Telemetry control cable
The product is equipped with a control cable to
manage one input contact and one output contact.
COLORS AND FEATURES OF THE CONTROL CABLE
Cable color
Function
Red
Input for activation by means of a volt free
relay contact
Green
Input for activation by means of a volt free
relay contact
White
Clean contact output (Follow)
Black
Clean contact output (Follow)
Tab. 2
Input contact: It allows a remote activation of the
illuminator by means of a clean contact placed
between the ends of the red and green cables. For a
proper operation, ensure that the photocell has been
disabled (Fig. 9, page 9). The input contact status is
the following:
• Open contact input (insulated red and green
poles): Illuminator on
• Short-circuit contact input (red and green poles
in short-circuit): Illuminator off
Output contact (Follow): The Follow output has
a clean contact in the white and black poles. The
Follow contact can be used to turn on or off other
illuminators simultaneously in the system or to verify
the camera day/night status. The Follow contact
status is the following:
• Open contact output (insulated white and black
poles): Illuminator on
• Short-circuit contact output (white and black
poles in short-circuit): Illuminator off