7

7.1.3 90/240Vac wiring version

Control cable

Power supply

Fig. 7

7.1.3.1 90/240Vac version power supply

cable

The device is Class I. Connection of the

yellow-green cable to the safety ground

is therefore necessary to ensure electrical

safety.

The illuminator is provided with a 2m power cable.
Blue, brown, yellow/green power cables: Connect

the brown cable to the phase, the blue one to the

neutral and the yellow-green one to the safety

ground.
For maximum distances and recommended cable

sections, refer to the relative paragraph.

7.1.3.2 Telemetry control cable

The product is equipped with a control cable to

manage one input contact and one output contact.

COLORS AND FEATURES OF THE CONTROL CABLE

Cable color

Function

Red

Input for activation by means of a volt free

relay contact

Green

Input for activation by means of a volt free

relay contact

White

Clean contact output (Follow)

Black

Clean contact output (Follow)

Tab. 2

Input contact: It allows a remote activation of the

illuminator by means of a clean contact placed

between the ends of the red and green cables. For a

proper operation, ensure that the photocell has been

disabled (Fig. 9, page 9). The input contact status is

the following:
Open contact input (insulated red and green

poles): Illuminator on

Short-circuit contact input (red and green poles

in short-circuit): Illuminator off

Output contact (Follow): The Follow output has

a clean contact in the white and black poles. The

Follow contact can be used to turn on or off other

illuminators simultaneously in the system or to verify

the camera day/night status. The Follow contact

status is the following:
Open contact output (insulated white and black

poles): Illuminator on

Short-circuit contact output (white and black

poles in short-circuit): Illuminator off