Connectors and connections, Installation example – Videotec PTH900 User Manual
Page 24
Pag. 6 PTH910 / PTH911 3201
Connectors and connections
The installation must be carried out only by qualified technical staff: an improper connection of the peripheral
units may cause the keyboard to be isolated from the rest of the system.
Installation example
Installation controlled by one operator with one monitor: the operator controls one pan & tilt motor and the
following camera functions FOCUS, ZOOM, DIAPHRAGM (IRIS):
MATERIAL USED
Control keyboard:
• 1 CBZ220/CBZ24 control
keyboard
Video handling:
• 1
monitor
Telemetry handling:
• 1 PTH910 / PTH911 pan & tilt
motor
•
1 motorized zoom lens
Installation example
One operator with more monitors, who controls a series of pan & tilt motors in mixed configuration (star and
cascade connection)
MATERIAL USED
Control keyboard:
• 1 DCS2 control keyboard
Video handling:
• 1 SW164OSM video switcher
• 2
monitors
• 4
cameras
• Telemetry handling:
• 1 DCMX serial data multiplexer
• 4 DTRX3 receivers
• 4 PTH910 / PTH911 pan & tilt motors
CBZ220/CBZ24
DTRX3
DTRX3
DTRX3
DTRX3
DCS2
SW164OSM
DCMX
7 wires-cable for the
control of the P&T head