Town Mongolian Barbecue Ranges User Manual
Page 8

FOOD SERVICE EQUIPMENT CO., INC. • 72 Beadel St. • BKLYN • NY 11222
8
OPERATING INSTRUCTIONS
1. Materials such as wood, compressed paper, and plant fibers that will ignite and burn must
not be exposed near this unit. Local safety codes should be complied with in respect to fire
avoidance.
2. The area around the unit must be kept clear to avoid restriction of air supply for combustion
or ventilation for exhaust.
3. The equipment must be installed with adequate clearance for air openings into the combustion
chamber, servicing and proper operation.
4. This appliance is designed and certified for use with either Natural Gas or LP gas. Verify gas
type is correct and matches the label plate on the unit.
5. The installation must conform with the National Fuel Gas Code, ANSI Z223.1, Natural Gas
Installation Code, CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2, as
applicable, including:
a. The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
1/2
psi
(3.45 kPa).
b. The appliance must be isolated from the gas supply piping system by closing its individual
manual valve during any pressure testing of the gas supply piping system at test pressures
equal or less than
1/2
psig (3.45 kPa).
6. The gas supply line must be of adequate size to insure maximum efficiency of the unit and
conform with the National Fuel Gas Code, ANSI-Z223.1.
7. Provision must be made to assure adequate supply of fresh air to this unit. This unit cannot
operate safely without sufficient air supply.
8. MBR installation is generally in a clear area as this unit is specifically designed for demonstra-
tion cooking. It is suitable for installation only on noncombustible floors that will tolerate
very high temperatures.
9. Your MBR must be operated under a hood to ensure adequate ventilation.
10. This unit should be operated only with bottom grease pans and scrap collector bin (/C models
only) in place.
11. DO NOT THROW AWAY THESE INSTRUCTIONS. This manual must remain with the unit
for future reference.