Fault
Possible cause
Remedial action
The light does not function.
The LED light is defective.
See chapter “Light (LED)” section.
Appliance was open too
long.
Light is switched off after
approx. 10 min.
When the appliance is closed and opened,
the light is on again.
Bottom of the refrigerator
compartment is wet.
The condensation channel
or drainage hole are blocked.
Clean the condensation channel
and the drainage hole. See chapter Cleaning
the appliance. Fig. 1
The temperature in
the refrigerator
compartment is too cold.
Temperature has been set
too low.
Increase the temperature.
The refrigerating unit
is switching on more
frequently and for longer.
Appliance opened
frequently.
Do not open the appliance unnecessarily.
The ventilation openings
have been covered.
Remove obstacles.
Appliance is not cooling,
temperature display and light
are lit.
Showroom mode is
switched on.
Hold down alarm button, Fig "/5, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.
Water dispenser is not
functioning.
Tap turned off.
Turn the tap on.
Filter on the water
connection is dirty.
Clean the filter.
Water supply is interrupted.
Water pressure too low.
Inform plumber.
Supply hose is kinked or
crushed. Fig. .
Ensure that the supply hose is installed
correctly.
Water dispenser is not
functioning.
The “lock” and “on/off”
buttons flash.
Water has escaped from the
pipe system.
The integrated AquaStop
system has interrupted the
water supply.
Turn off the water supply and inform customer
service (see chapter entitled “Alarm function”).
Water dispenser is not
functioning.
The “lock” button is still lit
even after it has been
pressed for three seconds.
Appliance door is not closed. Close appliance door properly.