beautypg.com

Service programmes – Siemens TE502206RW User Manual

Page 19

background image

15

en

Service Programmes

Depending on usage, the following

messages will appear on the display at

certain intervals:

Descale required!

or

Clean required!

or

Calc‘n‘Clean required!

The appliance should be cleaned or descaled

immediately using the corresponding

programme. You also have the option

of combining both processes with the

Calc‘n‘Clean function (see “Calc‘n‘Clean”).

If the service programme is not run as

instructed, the appliance may be damaged.

A

Warning

Each time you run the service programme,

you should follow the instructions for

using the descaling and cleaning agents.

Please observe the safety instructions

on the packaging of the cleaning agent.

Never interrupt the service programme!

Do not drink the liquids!

Never use vinegar, vinegar-based products,

citric acid or citric acid-based products!

Never put descaling tablets or other

descaling agents in the ground coffee

drawer or the drawer for cleaning tablets (4)!

Specially developed descaling and

cleaning tablets are available from

retailers or customer service (see

“Accessories”).

Descaling

Duration: approx. 25 minutes.

Important: If there is a filter in the water

tank (16), it needs to be removed before the

descaling programme is run.

If the message

Descale required!

appears

on the display, press the

e

off /

j

button

(12) for 3 seconds and then press the

start

button (10). The descaling programme will

start.

To descale the appliance before being

prompted, press the

e

off /

j

button (12) for

at least 3 seconds. Then press the

e

off /

j

button (12) briefly twice. Turn the upper

rotary knob (14) until

Start descaling

appears in the display.

To start the descaling procedure, press the

start button (10).

The display will guide you through the

programme.

Empty drip tray

Insert drip tray

● Empty drip tray (8) and replace them.

N.B.: If the water filter is activated, the

display will prompt you to remove the filter

and then press the

start button (10) again.

Remove the filter now if you have not

already done so. Press the

start button (10).

Fill descaler

Press start

● Pour lukewarm water into the empty

water tank (16) up to the

0.5 l mark

and then dissolve 1 Siemens descaling

tablet TZ80002 in it. When using

TZ60002, 2 tablets must be dissolved.

● Press the

start button (10).

Descale in progress

The descaling pro gramme will now run for

about 10 minutes.