15
en
Service Programmes
Depending on usage, the following
messages will appear on the display at
certain intervals:
Descale required!
or
Clean required!
or
Calc‘n‘Clean required!
The appliance should be cleaned or descaled
immediately using the corresponding
programme. You also have the option
of combining both processes with the
Calc‘n‘Clean function (see “Calc‘n‘Clean”).
If the service programme is not run as
instructed, the appliance may be damaged.
A
Warning
Each time you run the service programme,
you should follow the instructions for
using the descaling and cleaning agents.
Please observe the safety instructions
on the packaging of the cleaning agent.
Never interrupt the service programme!
Do not drink the liquids!
Never use vinegar, vinegar-based products,
citric acid or citric acid-based products!
Never put descaling tablets or other
descaling agents in the ground coffee
drawer or the drawer for cleaning tablets (4)!
Specially developed descaling and
cleaning tablets are available from
retailers or customer service (see
“Accessories”).
Descaling
Duration: approx. 25 minutes.
Important: If there is a filter in the water
tank (16), it needs to be removed before the
descaling programme is run.
If the message
Descale required!
appears
on the display, press the
e
off /
j
button
(12) for 3 seconds and then press the
start
button (10). The descaling programme will
start.
To descale the appliance before being
prompted, press the
e
off /
j
button (12) for
at least 3 seconds. Then press the
e
off /
j
button (12) briefly twice. Turn the upper
rotary knob (14) until
Start descaling
appears in the display.
To start the descaling procedure, press the
start button (10).
The display will guide you through the
programme.
Empty drip tray
Insert drip tray
● Empty drip tray (8) and replace them.
N.B.: If the water filter is activated, the
display will prompt you to remove the filter
and then press the
start button (10) again.
Remove the filter now if you have not
already done so. Press the
start button (10).
Fill descaler
Press start
● Pour lukewarm water into the empty
water tank (16) up to the
0.5 l mark
and then dissolve 1 Siemens descaling
tablet TZ80002 in it. When using
TZ60002, 2 tablets must be dissolved.
● Press the
start button (10).
Descale in progress
The descaling pro gramme will now run for
about 10 minutes.