For proper operation it is necessary to ensure constant voltage and it must not exceed or be lower
than 5% of the rated value.
Before making any electrical connection confirm voltage rating of the machine. There is a black
plastic box mounted on top of the reservoir.
WARNING!!!
Be sure there is no power to the machine before checking the following connections. It may
be necessary to lock out the machine for proper power disconnection.
Remove the two mounting screws that hold this box in place. Under this box you will see one of
the following possibilities in fig. 5. After confirming or changing this to the correct voltage
mount the cover with the two screws. Now, open the electrical panel on the transformer be sure it
is set for the correct output voltage.
Fig. 5
220 Volt connection
440 volt connections
WARNING!!!
Any damage caused by a faulty electrical connection is not covered by warranty.
Filling the pumping unit
To fill the pumping unit, use exclusively the oils indicated in the table on the next page or
equivalent. The environmental conditions must be considered before purchasing oil. To transfer
the oil from the container to the tank use an external filter as shown in Fig. 6 in order to prevent
the introduction of foreign material or liquids at the time of filling.
The amount of oil required for each model is described in the chart below.
A - Oil
B - Pump
C - Filter
D - Press Oil
40 Ton
10.5 Gallons
70 ton
10.5 Gallons
100 Ton 15.5 Gallons