11
Operating Temperature
After the machine has been put into operation at full rate, check that the oil temperature does not
exceed 140 F.
If the above described conditions are exceeded, check that the fluid used is not too viscous
(replace with more suitable fluid).
Using the unit with temperatures above those indicated above automatically forfeits
warranty.
Maintenance
Routine Maintenance operations must be carried out by authorized and trained personnel.
All maintenance or cleaning operations must be done with the machine properly locked out
in accordance with OSHA regulations.
Below is a table with the normal times for maintenance work:
HOURS
CHECK OIL
FILTER
CHECK
OIL
CHANGE
OIL
CHANGE OIL
FILTER
CHANGE AIR
FILTER
50
YES
100
YES
300
YES
YES
500
YES
YES
1000
YES
YES
YES
1500
YES
YES
2000
YES
YES
YES
Changing the oil
The oil will have to be changed periodically every 2000 operating hours or at least once a year.
Empty the unit tank by arranging a container of an adequate capacity to contain the quantity of
oil to be removed under the drainage plug at the bottom of the tank.
Remember to tighten the plug before filling the tank.
Disposing of the oil will have to be done in conformity with local and state laws along with
OSHA regulations. Hydraulic oil is considered special waste.
Filters
The filter must be frequently replaced during the first period of operation of the press and then at
regular intervals of time to be defined according to the conditions of use and the environment
where the machine is located.
It is recommended to change the filter after the first 100 hours of operation. After that
approximately every 500-600 hours.