Drf controllers, Operating specifications, Closed-loop valve controller – High Country Tek DRF Series User Manual
Page 5
021-DRF Rev A
DRF User Manual
5
Copyright © High Country Tek, Inc.
– 2013
DRF
Closed-loop Valve Controller
DRF Controllers
The DRF controller drives proportional solenoid valves in a closed loop system to follow a command signal. When
the feedback is greater than the command input, the coil receives full current; when the feedback is less than the
command input, the coil receives 0 current.
Once configured, the settings are permanently stored in the controller memory.
DRF Features
Easily configured using HCT Graphical User Interface (GUI) or HCT Hand Held Interface (HHI)
LED indication of power, output current and fault status
DIN-rail mount housing with removable terminal blocks
Multiple modes for open loop and closed-loop applications, programmable enable input
All input and output limits are independently adjustable
Adjustable output with short circuit protection, adjustable ramp up and ramp down rates
Fully adjustable PID control loop
Operating Specifications
Supply Voltage
9 to 32VDC
Supply Current
Valve current + 50mA (Quiescent Max)
Output Current
DRF-x06: 600mA MAX. per channel
DRF-x12: 1.2A MAX. per channel
DRF-x25: 2.5A MAX. per channel
Coil Resistance
2Ω MIN.
Reference Voltages
+10V, -10V @ 20mA (DRF-Vxx versions only)
Dither Frequency
30, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 1000 Hz
Analog Input Range
DRF-Vxx: -10V to 10V
DRF-Axx: 0 to 20mA
Analog Input Impedance
DRF-Vxx:
38kΩ
DRF-Axx:
250Ω
Analog Input Resolution
10 bits
Operating Temperature Range
-20º to 70º C; -40º to 85º C (storage)
Enclosure
Polyamide
Dimensions
Inch: 0.69 W x 4.50 H x 4.30 D; mm: 17.5 W x 114.5 H x 109.4 D