Valve Controller
Dual-coil valve control: Positive input drives channels 1 and 3, negative input drives channels 2 and 4. Channel
2 uses the input from channel 1. Channel 4 uses the input from channel 3. Ignore the input readings from
channel 3 & 4.
-0.3V input is in the deadband, channel 1 and
2 output current is 0A.
-6.5V input drives channel 4 output to 0.33A.
-7.3V input drives channel 2 output to 0.37A.
-9.5V input drives channel 4 output to 0.49A.