Parameter list, Valve controller – High Country Tek DRC Series User Manual
Page 10
![background image](/manuals/409834/10/background.png)
021-DRC Rev A
DRC User Manual
10
Copyright © High Country Tek, Inc.
– 2013
DRC
Valve Controller
Parameter List
The following table outlines the DRC parameters as well as the limits and units of measure for each parameter.
Parameter
Limits
Units
DRCx-xxx
Version #
C1 Mode
See Mode Description
Mode #
C1 Min input
-10 to +10.0
4 to 20.0
V
mA
C1 Max input
-10 to +10.0
4 to 20.0
V
mA
C1 Min output
0 to 600
1
mA
C1 Max output
0 to 600
1
mA
C1 Ramp up
0.0 to 120.0
Seconds
C1 Ramp down
0.0 to 120.0
Seconds
Previous 7 parameters repeated for all channels2
Dither frequency
30 to 1000
Hz.
C1 Command input
V (mA)
C1 Output current
mA
Previous 2 parameters repeated for all channels2
Supply voltage
Volts
Fault status
Fault
1
0 to 120 mA for
–01A version, 0 to 1.2 A for –12A version, 0 to 2.5 A for –25A version
2
Parameters starting with C1 are repeated for each channel and are displayed as C2 to C4