Closed-loop Controller
Application Examples
Single Solenoid Control
The MVP can drive a single solenoid with a signal of 0-5VDC, or 0-10VDC, or 4-20mA.
Use Mode 3 “open loop” to determine the max feedback range. Use Mode 1 “Normal” for closed-loop application.
Set the dither and output settings according to the valve specifications.
FUSE
+V Power Input
9 - 28VDC
Feedback
Brown PWR +
MVP-F
Electronic Valve
Controller
White Enable
GRN/YEL
Prop. PWM (Sourcing)
+5VDC @ 2mA
0-5VDC
Red Ref. Out
BLK Analog I/P
Blue GND
V
D
C
I/
P
m
A
I/
P
0-10VDC
V
D
C
I/
P
4-20mA
Connector GND
Screen
`
Min
fdbk
Max
fdbk
feedback
command
Min
cmd
Max
cmd
Black
– normal
Red - inverse