Hawkeye Float User Manual
Page 2
Hawkeye Industries Inc.
2
Remove the housing cap from the float guide
assembly and pull out the cable clamp and ex-
cess cable.
Turn the thumb screw counter clockwise to
loosen cable. Pull the cable and cable clamp
upwards until taut.
Turn thumb screw clockwise to secure cable.
Use the 9/16 wrench to tighten the sealing nut.
Loosen the cable clamp using the 5/16 wrench,
and reposition as near to the cable lock pocket
as possible.
Cut off the excess cable, leaving enough to
grab onto if future adjustement is required.
Position the remaining cable and cable clamp
into the pocket and replace the housing cap
with the pipe wrench. Repeat 5-9 with second
float gude cable lock assmbly.
MOVE
DOWNWARDS
LOOSEN
TIGHTEN
5.)
6.)
7.)
10.)
9.)
8.)
►
►
►
►
►
Float Guide Kit Installaton Complete
B.) Installing Float Guide Kit on an In-Service Tank
If the tank is in service and/or internal access is impossible, the float guide kit may still be installed with the aid of a hook long enough to
reach from the thief hatch to the float guide couplings and a Hawkeye float cable guide anchor plate.
Label the free end of the guide cable to identify which cable lock it is con-
nected to. Insert the end of the cable with the strap fork from the float
guide cable lock assembly into the 1-1/4 NPT couplings and feed down
into the tank.
Apply thread sealant on the bottom threads of the float guide cable lock
assembly housing and install into the 1-1/4 NPT coupling with the pipe
wrench. Repeat with the second float guide cable lock assembly.
1.)
2.)
►