Power-up in position or rpm, Decimal point programming – AMETEK 1995L Micro-Set PLS User Manual
Page 16

Chapter 3: Programming
Installation and Maintenance Manual
12
3.16: Power-Up in Position or RPM
The 1995L can power up displaying either Position or Scale Factor increments/sec. data.
The power-up mode is programmed by entering the following:
A)
Unit must be in the Program mode.
B)
Depress
. If a zero (0) is entered,
ENT
CIR# - 1 - 6
3
-
-
(0 or 1)
-
ENT
-
positional data will be displayed upon power-up; if a one (1) is entered, the unit will power up
displaying Scale Factor increments/sec.
3.17: Decimal Point Programming
A continuous, nonfloating decimal point may be programmed on the display. If a scale factor is selected
that needs a decimal point in order to properly display its resolution in engineering units, the following 50
series codes are used:
50 - No decimal point;
clears existing decimal point
123
51 - Tenths
12.3
52 - Hundreths
1.23
To program a decimal point, enter the following:
A)
Unit must be in the Program mode.
B)
Depress
.
Example:
CIR# 50
=
123
CIR# 51
=
12.3
CIR# 52
=
1.23
ENT
CIR# - 50 or 51
52
or
-