Chapter 3: Programming

Installation and Maintenance Manual

8

C)

will display the total number of setpoints available for use in

the currently selected active program.

D)

To display the active program, depress .

To change programs, with the unit in the Program mode, depress

.

NOTE: Program 0 is the first program. If 10 programs were previously selected using Code 770,

there will be programs 0-9.

CIR# 7

-

7

-

- 2 ENT

-

CIR#

- 7

-

-

ENT

-

-

ENT

7

1

(0 thru Highest Program Number)

3.8: Setpoints

Programming New Setpoints

A)

Unit must be in the “Program” mode.

B)

Select a limit switch circuit for programming. Depress .

The circuit number selected cannot exceed the number of output relays specified earlier using

CIR# 177. See Section 3.5: Selecting Number of Outputs.

C)

Depress . The will set the selected relay turn-on

point.

D)

Depress . . This will set the selected relay turnoff

point.

1)

On units where time-based circuits have been selected, the will be the

time interval that the relay will be active once the ON setpoint has been reached.

E)

Multiple ON and OFF setpoints can be programmed on each circuit. All decimal points will

flash when more than one setpoint exists on the selected circuit.

F)

An LS (Limit Switch) may not have the same value for both the ON point and the OFF point.

If a value is entered that is already a setpoint for that LS, only the new one will be used. For

example: If LS1 had an ON point at 100 and an OFF point of 100 was entered, the ON point

at 100 would be deleted, and the OFF point would then take its place. Assuming that these

were the only setpoints, the output would turn ON at 0 and OFF at 100.

The programmable limits are programmed based on “dwell on” and “dwell off” locations. The “dwell

on” typically represents the location at which a selected limit turns on and the “dwell off” represents the

location at which the limit turns off. The position locations for the “dwell on” and “dwell off” are based

CIR# -

-

(1 thru 30) - ENT

CIR OFF - (Desired Pos)

ENT

-

CIR ON - (Desired Pos)

ENT

CIR OFF