7.1 Changing seat and O-ring seal

(ZIVA

®

-Z / ZIVA

®

-G)

fig. 10

- Observe safety instructions
- Grease seat (pos. 2) when changing

Lubricant:

e.g. Berusoft 30 valve grease

obtainable from:

Carl Bechem GmbH, Weststrasse 120, D-58089 Hagen
or a lubricant suitable for this application.

ATTENTION!
- Always ensure that the lubricant is compatible with the medium.
- It is not safe to replace the O-ring seal (pos. 11) until the system has cooled

down and the plant is pressureless.

- For safety reasons we recommend that the O-ring seal (pos. 11) only be

changed when disassembled.

- Prior to disassembling the butterfly valve note points 10.0 and 11.0.
- When the butterfly valve is activated there is a crushing hazard between valve

disc and body.

- Maintenance work inside the pipeline (large nominal diameters) should only be

carried out when the butterfly valve is safely deactivated (disconnect actuator
from power supply).