VERIFY CELLULAR CONNECTIVITY
Confirm the following on the GUI (see Figure B) after logged into
the unit:
Activation:
“Succeeded” or “Unavailable”
Connection:
“Enabled”
IP Address: Populated with a network IP address
Signal Strength has GREEN bars populated. If you see any RED
bars represented under Signal Strength, please consult the User
Manual. Ethernet (Eth0) should show “Up” and show the network
issued IP address.
NOTE:
For SIM based models, if
“Unavailable” and connection
“Unknown” browse to the Network Tab -> Cellular Connection
-> Configuration
and input the APN in the field labeled “Enter
APN”, input username and password in appropriate fields if
supplied by your cellular carrier.
If you are unable to confirm this status on the Main page, please
refer to the SN 6000 User Guide for troubleshooting steps at
For more information on setting up Modbus features, please refer
to the SN-6000 User Guide available a
If you are able to confirm this status, then your unit is
successfully connected to the cellular network.
RED LION WIRELESS TECHNICAL SUPPORT
If you have followed all of the instructions up to this point, have
verified with your carrier that you are not having an authentication
problem, have verified that you have adequate cellular signal
reception, and your unit is still not communicating, then it is time to
contact Red Lion Wireless Technical Support at
or 1-877-432-9908 and we will be happy to
assist you in getting your unit operational.
HARDWARE STATUS LEDS
LED
State
Description
Power
ON
Power is applied to the router
Signal
ON
Excellent signal strength
FLASH
Flashes faster as signal is stronger
OFF
Very weak or no signal (less than -100dBm)
WAN
ON
Wireless link established, but no data activity
FLASH
Data transmitted/received on wireless network
RS232
ON
Link established with serial device but no data activity
FLASH
Data transmitted/received with attached serial device
Ethernet
ON
Link established with Ethernet device
FLASH
Data transmitted/received
SOFTWARE LICENSING TERMS & CONDITIONS
Software supplied with each Red Lion
Wireless’ product remains the
exclusive property of Red Lion Wireless. Red Lion Wireless grants with
each unit a perpetual license to use this software with the express
limitation that the software may not be copied or used in any other
product for any purpose. It may not be reverse engineered, or used for
any other purpose other than in and with the computer hardware sold by
Red Lion Wireless.
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy; and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause
harmful interference to radio communications, in which case the user will
be required to correct the interference at their own expense. Warning:
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
Information to the user:
If this equipment causes interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures: In order to meet FCC emissions limits, this
equipment must be used only with cables that comply with IEEE 802.3. If
necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user may find
the following booklet prepared by the Federal Communications
Commission helpful: “How to Identify and Resolve Radio-TV Interference
Problems”. This booklet is available from: U.S. Government Printing
Office, Washington, DC 20402, Stock No. 004-000-00345-4
WARRANTY
Red Lion Wireless provides a limited hardware warranty for the Industrial
Pro Router, which consists of the following: This warranty is effective for
three years from the delivery date of the
IndustrialPro™ Router to the
purchaser. The purchaser is responsible for returning the defective unit
to our factory, freight prepaid. If the
IndustrialPro™ Router is under
warranty, Red Lion Wireless will repair it and return it, freight prepaid, via
standard shipping. If the
IndustrialPro™ Router is not covered by the
warranty, we will notify you of the repair charges and not repair the
IndustrialPro™ Router without your permission. Repairs are guaranteed
for 90 days or the remainder of the warranty, whichever is longer.
Buyer’s remedies for breach of warranty shall be limited to repair or
replacement subject to adjustment as stated herein, or full or partial
adjustment to purchase price. The Red Lion Wireless Industrial Pro
Router are provided with the following warranty: Hardware maintenance
and repair is available on a return to factory basis. After this initial
period, configuration assistance will continue to be available on a
chargeable basis. Software support does not provide for custom code.
Custom changes are available as a chargeable option. The warranty only
covers items with a serial number. Cables and adapters are not
covered.
For complete and most up-to-date warranty information go to
Notice: UL Listed as BT-6xxx model