INSTALLATION ENVIRONMENT

The unit should be installed in a location that does not exceed the

maximum operating temperature and provides good air circulation. Placing
the unit near devices that generate excessive heat should be avoided.

Installation Procedure

The MLPS is shipped with all the necessary hardware to mount to the rear

of an installed Micro-Line unit. Refer to the instructions that correspond to
your Micro-Line unit for proper installation.

TROUBLESHOOTING

For further technical assistance, contact technical support at the appropriate

company numbers listed.

CUB4, DT8

The user must remove the common and V+ screw

terminals on the rear of the Micro-Line unit. Install
the 1/4" hex drive stand-offs into the common and
V+ terminals. The MLPS is then mounted to the
stand-offs using the screw terminals and square
washers. AC power can then be connected to
the terminal block of the MLPS.

EXISTING PANEL

BEZEL

GASKET

MOUNTING CLIP

STAND-OFF (2 TYP)

SCREW TERMINALS

SQUARE

WASHER

DC COMMON

OUTPUT POWER:

INPUT POWER:

YORK, PA. MADE IN U.S.A.

85-250 VAC, 50/60Hz, 7VA

12VDC UNREG.

@ 400mA

OPERATING TEMP: 0° TO 60°C

RED LION CONTROLS

MLPS1

MODEL

M3424X

TERMINAL

AC INPUT

+12V

STAND-OFF (2 TYP)

GASKET

RED LION CONTROLS

OPERATING TEMP: 0° TO 60°C

24VDC UNREG.

@ 200mA

85-250 VAC, 50/60Hz, 14VA

YORK, PA. MADE IN U.S.A.

OUTPUT POWER:

SCREW TERMINALS

MODEL

INPUT POWER:

MLPS2

DC COMMON

WASHERS

SQUARE

AC INPUT

TERMINAL

M4274X

+24V

EXISTING PANEL

MOUNTING CLIP

BEZEL

CUB5

The user must remove the common and V+

screw terminals on the rear of the Micro-Line
unit. Install the 3/16" hex drive stand-offs into
the common and V+ terminals. The MLPS is
then mounted to the stand-offs using the
supplied screws and square washers. AC
power can then be connected to the
terminal block of the MLPS.

Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls

China

Unit 101, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113-3688

Fax +86 21 6113-3683

Red Lion Controls

Europe

Printerweg 10

NL - 3821 AD Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls

India

54, Vishvas Tenement

GST Road, New Ranip,

Ahmedabad-382480 Gujarat, India

Tel +91 987 954 0503

Fax +91 79 275 31 350

This manual is related to the following products: