Figure 3 drying in two directions – Vaisala SHM40 User Manual
Page 19
Chapter 3 ____________________________________________ Humidity Measurement in Concrete
VAISALA _______________________________________________________________________ 17
d
hole for the
plastic tube
humidity
profile
0,4 × d
concrete
slab
BEFORE COATING
AFTER COATING
concrete
slab
hole for the
plastic tube
humidity
profile
coating
d
0,4 × d
1111-093
Figure 2
Drying in One Direction
In concrete slabs drying in two directions, the humidity is highest in the
middle of the slab. After coating, the slab is driest on the uncoated side.
concrete
slab
hole for the
plastic tube
humidity
profile
d
0,2 × d
BEFORE COATING
humidity
profile
hole for the
plastic tube
coating
d
0,2 × d
concrete
slab
AFTER COATING
1111-094
Figure 3
Drying in Two Directions
See also other documents in the category Vaisala Humidifiers:
- Calibration of Digital Transmitters with HMI41 (36 pages)
- Calibration of Series HMDW2030 and HMP130 Transmitter with HMI41 (14 pages)
- Calibration of Series HMDW6070 and HMP140 Transmitter with HMI41 (30 pages)
- HM34 (30 pages)
- HM40 (47 pages)
- HM44 (52 pages)
- HM70 (83 pages)
- HMD40 (1 page)
- HMD60 (4 pages)
- HMD70 (18 pages)
- HMDW110 (62 pages)
- HMDW80 (51 pages)
- HMI41 (74 pages)
- HMP41 (72 pages)
- HMK15 (39 pages)
- HMM100 (71 pages)
- HMM105 (23 pages)
- HMM211 (42 pages)
- HMM212 (36 pages)
- HMM213 (52 pages)
- HMP140 (28 pages)
- HMP155 (84 pages)
- HMP228 (115 pages)
- HMP230 (163 pages)
- HMP240 (130 pages)
- HMP260 (118 pages)
- HMP60 (71 pages)
- HMT100 (52 pages)
- HMT120 (87 pages)
- HMT130 (95 pages)
- HMT140 (76 pages)
- HMT310 (88 pages)
- HMT310 (105 pages)
- HMT330 (209 pages)
- HMT360 (97 pages)
- HMT360 (63 pages)
- HMT360N (110 pages)
- HMW40 (1 page)
- HMW90 (110 pages)
- RDP100 (14 pages)