Installation – Haws 2500.CT User Manual
Page 3
6/13
Model 2500.CT
Page 3 of 12
Installation
NOTES:
1. Keep the unit upright while moving, operating, or storing it.
2. This unit is certified for indoor use only. Be certain that the installation location for this
unit is level, is not in direct sunlight, is not next to a heat source, and will not freeze. 4” of
clearance around the unit must be maintained to facilitate air circulation.
3. Instal
l this unit within 6’ of its power source. Do not use extension cords or two-pronged
power outlets.
4. Do not use with water that is microbiologically unsafe or unknown quality without
adequate disinfection before or after the system. Systems certified for cyst reduction may
be used on disinfected waters that may contain filterable cysts.
5. For all plastic 1/4" push-in type fitting connections, only connect NSF-61 copper or plastic
tubing. Stainless steel or glass tubing is not recommended. The following assembly
instructions must be followed to ensure a watertight connection:
a.
Cut tubing square and clean.
b.
Mark 11/16” from end of tube.
c.
Push tube into the fitting until it bottoms out.
d.
To remove, depress collet and pull tubing out.
Cooler Installation
Step 1:
Remove the bright orange Trademark Usage Guidelines Agreement label on the filter (see
below), thereby accepting the guidelines. The label reads as follows:
Removal of this label signifies you or an appropriate owner’s agent will comply with all
BRITA® Trademark Usage Guidelines as well as maintain the unit to the standards as
first installed. Detailed information noting requirements can be found in the Owner’s
Manual.
Screw the filter cartridge into the filter head.
PARTS LIST: 1 Brita
®
Hydration Station
®
, 1 drip tray, 1 filter cartridge, 1 filter head, 1 pressure
regulator with plastic tubing, 1 115VAC power cord.
OPTIONAL ACCESSORIES: Model 2518 1/4" leak-detecting valve.
RECOMMENDED TOOLS: Phillips screwdriver, tubing cutter, adjustable wrench.
REQUIRED PARTS (NOT SUPPLIED): Water supply shutoff valve
, 1/4” tubing (for water supply)
SUPPLY LINE: 1/4" tubing. Cold water supply only. Intended for municipal water only.
ELECTRICAL CONNECTIONS: 115VAC, 60HZ, approx. 4.7A.
SIZE: Approximately 17-5/16
”H x 14-1/4”W x 19-3/4”D.